Category | unit | CADY160 | CADY200 | CADY250A |
Rated input voltage | V | Phase 220 | Phase 220 | Phase 220 |
Rated output voltage | A | 160 | 200 | 250 |
Rated Frequency | HZ | 50/60 | 50/60 | 50/60 |
Rated Input Power | KVA | 5KVA | 6KVA | 7.9KVA |
Nominal utilization (Temperature 25'c) |
% | 40@3.2θ,160A 60@2.6θ 130A |
40@4θ,200A 60@3.2θ 150A |
40@5θ,250A 60@4θ 250A |
Size ( L X W X H) | 245x450470)x240 | |||
Weight | Kg | 7.9 | 10 | 15 |
TIG 300 | 500TP | ||||
Input Power | 220 1ph/380Vac 3ph select, 60/50Hz | 220 1,3ph/380Vac 3ph combine, 60/50Hz | |||
Utilization | GTAW | 60% | 300A | 60% | 500A |
80% | 250A | 80% | 350A | ||
100% | 200A | 100% | 250A | ||
SMAW | 40% | 230A | 40% | 300A | |
60% | 200A | 60% | 200A | ||
80% | 180A | 80% | 180A | ||
No-load voltage | 60Vdc | 80Vdc | |||
Rated load voltage | GTAW | 22Vdc | 30Vdc | ||
32Vdc | 28Vdc | ||||
Output Current Range | SMAW | 10~300A | 5~500A | ||
20~230A | 20~230A | ||||
Down Slope Function | 1~10 sec | 1~10 sec | |||
Crater current | 30% of Welding current | ||||
Pulse current | 50% of Welding current | ||||
Arc force | Voltage setting | ||||
Shield Gas control Post-Flow time | 0.1~15sec | 0.1~15sec | |||
Control Method | 100KHz F.E.T inverter | 18~20KHz I.G.B.T inverter | |||
Rated input current | 14A/380Vac,37A/220Vac | 27A/380Vac,71A/220Vac(1ph) | |||
Rated input power | 8.3KVA(8KW) | 15.8KVA(15KW) | |||
Factor | 0.98 | 0.98 | |||
Insulation Class | F | F | |||
Protection Class | IP23 | IP23 | |||
Temperature | -20C~50C | -20C~50C | |||
Size ( L X W X H) | 480X205X355 | 640X380X575 | |||
Weight | 19Kg | 40Kg |
350GP | 500GP | |||
Input Power | 220/380Vac, 3ph, 60/50Hz | 220/380Vac, 3ph, 60/50Hz | ||
Utilization | GTAW | 60% | 300A | 500A |
80% | 250A | 400A | ||
100% | 200A | 300A | ||
SMAW | 40% | 250A | 300A | |
60% | 200A | 220A | ||
80% | 180A | 200A | ||
No-load voltage @ 380Vac | 78Vac 71Vdc | 80Vac 72Vdc | ||
Rated load voltage @ 380Vac | AC GTAW | 35Vdc | 40Vdc | |
DC SMAW | 24Vdc | 30Vdc | ||
SMAW | 32Vdc | 38Vdc | ||
Output Current Range | GTAW | 5~300A | 5~500A | |
SMAW | 1~250A | 10~250A | ||
Down Slope Function | 1~10sec | |||
Range (Pulse/Initial/Crater) | 5~300A | 5~500A | ||
Pulse | Frequency | 0.5~500Hz | 0.5~500Hz | |
Current width | 0~100% | 0~100% | ||
Shield Gas control Post-Flow time | Pre-Flow time | 0.3sec (set board) | 0.3sec (set board) | |
Post-Flow time | 0.1~20 | 0.1~20 | ||
Control Method | I.G.B.T inverter | I.G.B.T inverter | ||
Rated input current | 14A/380Vac,25A/220Vac | 14A/380Vac, 25A/220Vac | ||
Rated input power | 10KVA(9.5KW) | 18KVA(15.3KW) | ||
Factor | 0.92 | 0.85 | ||
Insulation Class | F | F | ||
Protection Class | IP23 | IP23 | ||
Temperature | -20C~50C | -20C~50C | ||
Size ( L X W X H) | 640X380X580(615X370X575) | 640X380X580 | ||
Weight | 45Kg | 53kg |
MIG251 | MIG253 | 350DX | 500DX | 650DX | ||
Input power | 220Vac,1ph, 60/50Hz |
380Vac,3ph, 60/50Hz |
220/380Vac, 3ph, 60/50Hz | 220/380Vac, 3ph, 60/50Hz | 220/380Vac, 3ph, 60/50Hz | |
Utilization | 60% 200A | 60% 250A | 60% 350A/34Vdc | 60% 500A/42Vdc | 60% 650A/50Vdc | |
80% 160A | 80% 180A | 80% 300A/32Vdc | 80% 400A/38Vdc | 80% 500A/42Vdc | ||
40% 250A | 50% 250A | 100% 250A/28Vdc | 100% 300A/32Vdc | 100% 400A/38Vdc | ||
Output Current Range | 30A/15Vdc~270A /28Vdc |
30A/15Vdc~270A /29Vdc |
30Adc~350Vdc | 30Adc~550Adc | 30Adc~650Adc | |
No-load Voltage | 12Vdc~56Vdc | 12Vdc~54Vdc | 72Vdc | 72Vdc | 72Vdc | |
Rated Input Current | 36A | 12A | 12A | 59A/380Vac, 80A/220Vac |
74A/380Vac, 105A/220Vac | |
Rated Input Power | 8.1KVA(7.6KW) | 8.1KVA | 14KVA(12KW) | 32KVA(25.3KW) | 40KVA(32KW) | |
Welding rods speed | 3~15M/min | 3~15M/min | 1~16M/min | 1~21M/min | 1~23M/min | |
Factor | 0.93 | 0.93 | 0.85 | 0.85 | 0.8 | |
Welding rods length | Fe,Ss | 0.6~1.0mm | 0.6~1.2mm | 0.8~1.2mm | 0.9~1.6mm | 0.9~1.6mm |
C | 0.8~1.0mm | 0.8~1.2mm | 0.8~1.2mm | 1.0~1.6mm | 1.0~1.6mm | |
AI | 1.0~1.2mm | 1.0~1.2mm | 1.0~1.2mm | 1.2~1.6mm | 1.2~1.6mm | |
Spot welding time | 0.2~2sec | 0.2~2sec | x | x | x | |
Welding wire tray | 20Kg, dia 300mm | 20Kg, dia 300mm | External | External | External | |
Sub Power | 100Vac | 100Vac | 100Vac | |||
Insulation Class | F | F | F | F | F | |
Protection Class | IP21 | IP21 | IP21 | IP21S | IP21S | |
Temperature | -10C~40C | -10~40C | -20~50C | -20~50C | -20~50C | |
Size ( L X W X H) | 600X240X495 | 640X380X580 (615X370X575) |
640X380X580 (615X370X575) |
640X380X580 (615X370X575) |
||
Weight | 40Kg | 40Kg | 45Kg | 55Kg | 60Kg |
List | Unit | 50P | 100P | 200P | 300P | |
Rated input voltage | V | Single Phase/ 3 phase, AC 200V | ||||
Rated Input Frequency | Hz | 50/60 | ||||
Rated input capacity | kVA | 2.5 | 4.5 | 7.5 | 12 | |
Rated output current | A | 50 | 100 | 200 | 300 | |
No-load Voltage | V | 100 | 100 | 100 | 100 | |
Rated load voltage | V | 35 | 40 | 45 | 45 | |
Rated utilization | % | 100 | 100 | 100 | 60 | |
Control Method | 1GBT INVETER | |||||
Cooling system | Torch water-cooled, forced wind-cooled | |||||
Dimension | mm | 400x1010x650 | ||||
Weight | kg | 75 | 80 | 85 | 90 | |
Output Current | Initial current | 0.1~50 | 1~100 | 4~200 | 4~300 | |
base current | 0.1~51 | 1~101 | 4~200 | 4~300 | ||
Pulse current | 0.1~52 | 1~102 | 4~200 | 4~300 | ||
Crater current | 0.1~53 | 1~103 | 4~200 | 4~300 | ||
Current rise time | sec | 0~5 | ||||
Current fall time | sec | 0~5 | ||||
Initial gas flow | sec | 0~5 | ||||
late gas flow | sec | 0~20 | ||||
Pulse width | % | 15~85 | ||||
Arcspot time | sec | 0~5 | ||||
Ppilot Arc | Current | A | 7 | |||
Load Voltage | V | 15 | ||||
Rated Utilization | % | 100 | ||||
Gas | Ppilot Gas | Liter/min | 0~1.0 | |||
Shild Gas | 0~1.0 | |||||
Water cooler | Pressure | kg/cm2 | 2 | |||
Flux | liter/min | 0.5~1.5 |